VersaTRAK® IPm® RTU

Industrial Automation

The VersaTRAK IPm™ is the ultimate, open industrial RTU. This versatile RTU is loaded with powerful communications and advanced programming capabilities.

 

The Ultimate RTU with the Power of Completely Open LINUX Software

Though it is built-on the open LINUX operating system, no knowledge of LINUX is required in most applications. Get all the benefits of open LINUX with no extra effort. The VersaTRAK IPm  is 100% compatible with Sixnet's legacy VersaTRAK RTU. All existing ISaGRAF user programs will load and run in an IPm without any changes.

To learn more about our VT-IPm Industrial RTU, simply contact sales@sixnet.com, call +1 518 877 5173 or request an industrial networking product CD now.

Industrial RTU Product Highlights

  • Stand-alone control of remote sites
  • Flexible open-source LINUX software
    • IPm add-on software
    • Embedded LINUX firmware
  • Datalogging and time-stamping
    • Datalog server
    • Redundant logging
  • Never lose data again
  • ISaGRAF IEC 61131 programming
  • Limitless multi-user connectivity
  • Advanced communications
    • DNP3, SNMP, PPP and more
    • Modbus/TCP, ASCII and RTU
  • Advanced security capabilities
  • True open system design
  • Unlimited I/O expansion
  • Peer to peer I/O transfer capability
  • Master terminal unit / concentrator
  • UL, CSA, CE, DNV and Zone 2 rated

To learn more about our VT-IPm Industrial RTU, simply contact sales@sixnet.com, call +1 518 877 5173 or request an industrial networking product CD now.

Performance Specifications

  • Industrial PowerPC: (32 bit data bus)
  • Operating system: Embedded LINUX
  • Dynamic memory (RAM): 16 Megabytes – 32bit, 0 wait states
  • Program memory (Flash): 16 Megabytes
  • Datalogging memory (RAM): 512K or 2 MB (battery-backed)
  • Maximum local I/O: 640
  • Maximum distributed I/O: 50,000+ (application dependent)
  • Datalogging support: Sixnet Sixlog
  • IEC 61131 programming: Sixnet ISaGRAF
  • High Level C programming: LINUX open software

Ethernet Port

  • 10/100BaseTx (auto-detecting)
  • Connection RJ45 (auto-crossover)
  • Protocols: TCP/IP, ARP, UDP, ICNP, DHCP,
  • Modbus/TCP, Sixnet and more

Serial Port

  • Up to 115,200 baud
  • RS232 Port A RJ45 (TD, RD, CTS, RTS, CD, DTR, DSR, GND)
  • RS232 Port B RJ45 (TD, RD, CTS, RTS, CD, DTR, DSR, GND)
  • RS485 Port C Screws (485+, 485-, GND) (2-wire half-duplex)
  • RS232 Port D Screws (TD, RD, CTS, RTS, GND)
  • Protocols (master and slave): Sixnet and Modbus RTU/ASCII;
    many others available in LINUX
  • Flow Control Hardware, software, RTS-party (for radios and RS485)

Environmental

  • DIN-rail or flat panel mount
  • Input power 10-30 VDC
  • Input current 100 mA @ 24 VDC (typical)
  • Temperature -40 to 70°C (-40 to 85°C storage)
  • Humidity 5% to 95% RH (non-condensing)
  • Flammability UL 94V-0 materials
  • Electrical Safety UL 508, CSA C22.2/14; EN61010-1 (IEC1010); EMI emissions FCC part 15, ICES-003, Class A; EN55022; EN61326-1;
  • EMC immunity EN61326-1 (EN61000-4-2,3,4,6); Surge withstand IEEE-472 (ANSI C37.90)
  • Vibration IEC68-2-6
  • Hazardous locations UL 1604, CSA C22.2/213, (Class 1, Div 2, Groups A,B,C,D) Cenelec EN50021 Zone 2 

Specifications are subject to change. Contact Sixnet to learn more.


To learn more about our VT-IPm Industrial RTU, simply contact sales@sixnet.com, call +1 518 877 5173 or request an industrial networking product CD now.

Part Number
(Module with wiring base)
DI DO AI AO Description
E2 or EB-MIX24880-D
24
8
8
0
Combination I/O with 1 isolated input counter *
E2 or EB-MIX24882-D
24
8
8
2
Combination I/O with 2 analog outputs **
E2 or EB-32DI24-D
32
-
-
-
32 inputs (10-30 VDC)
E2 or EB-16DI24-D
16
-
-
-
16 individually isolated channels, 10-30 VDC/VAC with counters
E2-16DIAC-D
16
-
-
-
16 individually isolated inputs,120 VAC nominal
E2 or EB-32DO24-D
-
32
-
-
High density discrete outputs
E2 or EB-16DO24-D
-
16
-
-
Individually isolated 1 Amp outputs with self-resetting fuses
E2 or EB-32AI20M-D
-
-
32
-
High density 16 bit 4-20mA inputs with self-resetting fuses
E2 or EB-32AI10V-D
-
-
32
-
Voltage inputs
E2 or EB-16AI20M-D
-
-
16
-
16 channels 4-20mA inputs with self-resetting fuses
E2 or EB-8AO20M-D
-
-
-
8
4-20mA analog outputs
E2 or EB-16AI-8AO-D
-
-
16
8
16 4-20mA inputs plus 8 4-20mA outputs
E2 or EB-16ISOTC-D***
-
-
16TC
-
Instrumentation thermocouples
E2 or EB-8ISOTC-D***
-
-
8TC
-
Instrumentation thermocouples
E2 or EB-16ISO20M-D***
-
-
16
-
Isolated 4-20mA inputs
E2 or EB-10RTD-D
-
-
10
RTD
-
RTD (100 Ohm platinum), -200 to 850°C.


To learn more about our VT-IPm Industrial RTU, simply contact sales@sixnet.com, call +1 518 877 5173 or request an industrial networking product CD now.

Selecting the 512K or 2 Megabyte Memory Option

  • 512K of datalogging memory can store up to 250,000 analog values
  • 2 Megabytes of datalogging memory can store up to 1,000,000 analog values

How Much Datalogged Information Can be Stored?

Each Sixlog file is allocated a fixed amount of memory. Each record typically contains a time stamp (4 bytes), analog values (2 bytes each), and discrete values (8 per byte). The size of the record is automatically computed and displayed for you by the Sixlog software. The overall storage time (until the oldest data in a full file is overwritten by new data) is computed as:
Longest storage = (file size) x (capture interval) / (bytes per record)

Example:

16 analog values plus a time stamp are logged every 5 minutes into a 512K file.
Oldest data = 512,000 (approx) x 5 minutes / 36 bytes /record = 71,111 Minutes (49 days)

By default, the VT-IPM-1410 has more than 400K for datalogging and the VT-IPM-2410 has more than 1.9 Megabytes.


Adding I/O modules to a VersaTRAK IPm

Any combination of SixTRAK, EtherTRAK and RemoteTRAK I/O modules can be connected to a VersaTRAK IPm. A single VersaTRAK IPm supports up to 1,024 SixTRAK I/O and will interface with up to approximately 50,000 EtherTRAK and/or RemoteTRAK I/O.

Why VersaTRAK IPm Instead of other Sixnet Controllers?

  • VersaTRAK IPm offers more communication ports (RS232 and Ethernet) than are available on other Sixnet gateways and RTUs.
  • The embedded LINUX operating system in the VersaTRAK IPm offers greater programming flexibility and performance.


To learn more about our VT-IPm Industrial RTU, simply contact sales@sixnet.com, call +1 518 877 5173 or request an industrial networking product CD now.


Recommended RTUs

Part Number
RS232
RS485
Eth
Static RAM
Dyn RAM
Flash
VT-IPM-1410 3 1 1 512K 16MB 16MB
ST-IPM-6350*
2
1
5
2 MB
64MB
128MB

* Best Value


Legacy RTUs
Part Number
RS232
RS485
Eth
Static RAM
Dyn RAM
Flash
VT-IPM-2410 3 1
1
2MB
16MB
16MB
ST-IPM-1350
2
1
5
512K
16MB
16MB
ST-IPM-2350
2
1
5
2 MB
16MB
16MB

Legacy Controller's
Part Number
RS232
RS485
Eth
Static RAM
Dyn RAM
Flash
ST-GT-1210 1 1
1
512K
16MB
16MB
ET-GT-ST-3 1 0 2 - - -*
*Memory is not applicable because unit is not programmable.

Replacement Guide

Legacy Product Replacement RTUs
ST-IPm-1350
ST-IPm-635
ST-IPm-2350
ST-IPm-635
VT-IPm-2410
ST-IPm-6350 or VT-IPm-1410
VT-MIPm-131-D
VT-MIPm-135-D
VT-MIPm-241-D
VT-MIPm-245D
ST-GT-1210 Any IPm
ET-GT-ST-3 ST-IPm-6350 or VT-IPm2m-113